{"id":4289,"date":"2026-11-08T09:50:16","date_gmt":"2026-11-08T09:50:16","guid":{"rendered":"https:\/\/ycpcbs.com\/bom-cpl-files-pcb-assembly\/"},"modified":"2026-11-10T03:08:28","modified_gmt":"2026-11-10T03:08:28","slug":"bom-cpl-files-pcb-assembly","status":"publish","type":"post","link":"https:\/\/ycpcbs.com\/ja\/bom-cpl-files-pcb-assembly\/","title":{"rendered":"BOM and CPL Files for PCB Assembly: What Buyers Need to Submit"},"content":{"rendered":"<p>Two files decide whether an assembly order starts cleanly: the <strong>cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits<\/strong> (which parts) and the <strong>CPL<\/strong> (where they go). Neither is hard to produce. Both are easy to produce badly, and the failures are quiet \u2014 a missing MPN becomes a substitution, a rotation offset becomes a part soldered sideways, a package mismatch becomes a footprint that does not fit.<\/p>\n<p>This guide is a quality standard for both files, independent of which EDA tool you use. YC PCB runs turnkey assembly and reviews thousands of BOM\/CPL pairs; the errors below are the ones that come back most often.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ycpcbs.com\/wp-content\/uploads\/2026\/06\/\u5de5\u7a0b\u5e08\u5ba1\u6838\u8d44\u6599.jpg\" alt=\"CAM engineer reviewing Gerber and BOM files\" width=\"1024\" height=\"576\" \/><\/p>\n<h2>What Is a CPL File in PCB?<\/h2>\n<h3>The four fields that reach the machine<\/h3>\n<p>CPL stands for <strong>centroid, pick-and-place, or component placement list<\/strong> \u2014 the file is the same thing under three names. It contains, for every component to be placed:<\/p>\n<ul class=\"post-list\">\n<li><strong>Reference designator<\/strong> (R1, C14, U3)<\/li>\n<li><strong>X and Y coordinates<\/strong> relative to a defined origin<\/li>\n<li><strong>Rotation<\/strong> in degrees<\/li>\n<li><strong>Layer<\/strong> (top or bottom)<\/li>\n<\/ul>\n<p>Some tools export additional fields (package, value, mirror flag). The four essentials are reference, X, Y and rotation.<\/p>\n<p>The CPL is what the placement machine reads. If the origin, the rotation convention or the layer flag is wrong, the machine places parts confidently in the wrong place.<\/p>\n<h2>What Files Are Needed for PCB Assembly?<\/h2>\n<table>\n<thead>\n<tr>\n<th>File<\/th>\n<th>Contents<\/th>\n<th>Owner<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Gerber (RS-274X)<\/td>\n<td>Bare board fabrication data<\/td>\n<td>Design team<\/td>\n<\/tr>\n<tr>\n<td>Excellon drill<\/td>\n<td>Hole positions and sizes<\/td>\n<td>Design team<\/td>\n<\/tr>\n<tr>\n<td>cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits<\/td>\n<td>Reference, quantity, value, package, MPN, manufacturer<\/td>\n<td>Design\/procurement<\/td>\n<\/tr>\n<tr>\n<td>CPL \/ centroid<\/td>\n<td>Reference, X, Y, rotation, layer<\/td>\n<td>Design team<\/td>\n<\/tr>\n<tr>\n<td>Assembly drawing<\/td>\n<td>Polarity, orientation, special notes<\/td>\n<td>Design team<\/td>\n<\/tr>\n<tr>\n<td>Test specification<\/td>\n<td>What pass means, test method<\/td>\n<td>Design + quality<\/td>\n<\/tr>\n<tr>\n<td>Panelisation drawing<\/td>\n<td>Array format, fiducials, break-away<\/td>\n<td>Design + fabricator<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>A common mistake is to send Gerber plus BOM and assume the assembly house can derive placement from the Gerber. It cannot do so reliably \u2014 the Gerber has pads, not components.<\/p>\n<h2>BOM: The Fields That Matter<\/h2>\n<h3>Ten fields, one of them non-negotiable<\/h3>\n<p>A BOM without manufacturer part numbers is a shopping list, not a specification. Include:<\/p>\n<table>\n<thead>\n<tr>\n<th>cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits<\/th>\n<th>cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits<\/td>\n<td>cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits<\/td>\n<\/tr>\n<tr>\n<td>cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits<\/td>\n<td>cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits<\/td>\n<\/tr>\n<tr>\n<td>cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits<\/td>\n<td>cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits<\/td>\n<\/tr>\n<tr>\n<td>cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits<\/td>\n<td>Must match the land pattern on the board<\/td>\n<\/tr>\n<tr>\n<td>Manufacturer part number (MPN)<\/td>\n<td>The actual specification<\/td>\n<\/tr>\n<tr>\n<td>Manufacturer name<\/td>\n<td>Needed for sourcing and cross-reference<\/td>\n<\/tr>\n<tr>\n<td>\u8aac\u660e<\/td>\n<td>Human check during review<\/td>\n<\/tr>\n<tr>\n<td>Preferred alternate<\/td>\n<td>Avoids a stop-and-ask later<\/td>\n<\/tr>\n<tr>\n<td>Criticality flag<\/td>\n<td>Marks parts where no substitution is allowed<\/td>\n<\/tr>\n<tr>\n<td>Datasheet link or revision<\/td>\n<td>Resolves ambiguity on obscure parts<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>For boards with variants (population options), add a variant column or a separate BOM per variant. Assembly houses cannot infer \"this part is only fitted on the 8 GB version\" from a note in an email.<\/p>\n<h2>The Rotation Trap<\/h2>\n<h3>Why 0\u00b0 means four different things<\/h3>\n<p>Rotation is the most frequent cause of a first-article failure, and it is not the designer's fault in any obvious way: <strong>different EDA tools define 0\u00b0 differently.<\/strong><\/p>\n<ul class=\"post-list\">\n<li>Some tools measure rotation from the component's pin 1 orientation<\/li>\n<li>Others measure from the footprint's local axes<\/li>\n<li>Some export mirrored rotation for bottom-side parts, others do not<\/li>\n<li>Some export rotation in a non-standard direction (clockwise versus counter-clockwise)<\/li>\n<\/ul>\n<p>The result: a file that is internally consistent but displaced by 90\u00b0 or 180\u00b0 at the machine.<\/p>\n<p>The practical defences:<\/p>\n<ol class=\"post-list\">\n<li><strong>Send an<\/strong> <a href=\"https:\/\/ycpcbs.com\/ja\/pcb-assembly-quote-requirements\/\"><strong>assembly drawing<\/strong><\/a> <strong>with pin-1 markers<\/strong> for every polarised part.<\/li>\n<li><strong>Run a first article<\/strong> and check polarised parts physically before volume.<\/li>\n<li><strong>State the rotation convention<\/strong> if you know it, or ask the assembly house which convention their machine expects.<\/li>\n<li><strong>Check bottom-side parts separately.<\/strong> Mirror flags cause the most subtle errors.<\/li>\n<\/ol>\n<h2>Can KiCad Generate a BOM?<\/h2>\n<p>Yes. KiCad produces a BOM from the schematic through its BOM export (a Python script or the built-in exporter), grouping components by value and footprint. The output is a CSV you can edit.<\/p>\n<p>Three things to fix before sending a KiCad BOM:<\/p>\n<ul class=\"post-list\">\n<li><strong>Add MPNs.<\/strong> KiCad will export whatever fields exist; if you never filled a manufacturer part number field, the BOM has no MPN.<\/li>\n<li><strong>Check the grouping.<\/strong> Grouping by value and footprint can merge parts that are electrically similar but come from different manufacturers.<\/li>\n<li><strong>Add DNP handling.<\/strong> cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits.<\/li>\n<\/ul>\n<h2>cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits<\/h2>\n<p>cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits <strong>cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits<\/strong>. cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits.<\/p>\n<p>cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits<\/p>\n<ul class=\"post-list\">\n<li><strong>cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits.<\/strong> cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits.<\/li>\n<li><strong>cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits<\/strong> unless the assembly house asks otherwise, and state the unit.<\/li>\n<li><strong>Select both sides<\/strong> if the board is double-sided.<\/li>\n<li><strong>Check the rotation column<\/strong> against a known part. Put a deliberately asymmetric footprint (a SOT-23 or an SOIC) near the origin and verify its rotation visually in the assembly drawing.<\/li>\n<\/ul>\n<p>The same logic applies to Altium, Eagle, OrCAD and PADS: the export exists, and the export defaults are not always what the machine wants.<\/p>\n<h2>Pre-Send Checklist for BOM and CPL<\/h2>\n<p><strong>BOM:<\/strong><\/p>\n<ol class=\"post-list\">\n<li>Every line has an MPN and a manufacturer<\/li>\n<li>Every reference designator on the board appears in the BOM, and vice versa<\/li>\n<li>Package fields match the footprints on the board<\/li>\n<li>DNP parts are flagged<\/li>\n<li>Variants are documented separately<\/li>\n<li>Alternates are listed, or the no-substitution rule is stated<\/li>\n<li>Quantities match the board and the order quantity<\/li>\n<\/ol>\n<p><strong>CPL:<\/strong><\/p>\n<ol class=\"post-list\">\n<li>Origin matches the fabrication origin<\/li>\n<li>Units stated (mm or mil)<\/li>\n<li>Both sides included for double-sided boards<\/li>\n<li>Rotation verified on at least one polarised part per side<\/li>\n<li>Layer\/mirror flag checked for bottom-side parts<\/li>\n<li>Reference designators match the BOM exactly<\/li>\n<li>No mechanical or fiducial features exported as components<\/li>\n<\/ol>\n<h2>Where Assembly Orders Break Down<\/h2>\n<p><strong>BOM references that do not exist on the board.<\/strong> A leftover designator from a deleted component stops the file review.<\/p>\n<p><strong>Package mismatch.<\/strong> The BOM says QFN-32 but the footprint is QFP-32. This is caught at DFM review if the reviewer checks, and at assembly if they do not.<\/p>\n<p><strong>CPL includes fiducials and tooling holes.<\/strong> The machine tries to place components on them. Filter non-component features out.<\/p>\n<p><strong>Mixed units.<\/strong> A CPL in mils with a Gerber origin in millimetres produces a systematic offset that looks like a programme bug.<\/p>\n<p><strong>Value-only BOM for a critical part.<\/strong> The supplier picks an equivalent, and \"equivalent\" is a judgement about a part you considered critical.<\/p>\n<h2>cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits<\/h2>\n<ol class=\"post-list\">\n<li>Confirm the design revision, and label every file with that revision.<\/li>\n<li>Send Gerber, drill, BOM, CPL, assembly drawing and test spec as one package.<\/li>\n<li>State the units and the origin for the CPL.<\/li>\n<li>Flag critical parts where no substitution is allowed.<\/li>\n<li>Document variants and DNP parts explicitly.<\/li>\n<li>Ask the assembly house to run a BOM\/CPL consistency check before quoting.<\/li>\n<li>Approve a first article with a photo report before volume.<\/li>\n<li>cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits.<\/li>\n<\/ol>\n<h2>\u3088\u304f\u3042\u308b\u8cea\u554f<\/h2>\n<h3>cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits<\/h3>\n<p>cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits.<\/p>\n<h3>cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits<\/h3>\n<p>cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits.<\/p>\n<h3>cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits<\/h3>\n<p>cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits.<\/p>\n<h3>cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits<\/h3>\n<p>cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https:\/\/developers.cloudflare.com\/workers\/wrangler\/configuration\/#limits.<\/p>\n<h2>Why YC PCB<\/h2>\n<ul class=\"post-list\">\n<li>20+ years of PCB and PCBA manufacturing, exporting to 20+ countries<\/li>\n<li>BOM management and component sourcing, with alternates confirmed before build<\/li>\n<li>File review that checks BOM, CPL, Gerber and assembly drawing against each other before quoting<\/li>\n<li>SMT, THT\/DIP, mixed technology, BGA\/QFN\/Micro-BGA with X-Ray inspection<\/li>\n<li>AOI, electrical test, ICT and FCT per project scope<\/li>\n<li>DFM\/DFA review before production; NDA available for customer IP<\/li>\n<li>ISO 9001 and UL certification; RoHS compliance documentation on request<\/li>\n<\/ul>\n<p><a href=\"https:\/\/ycpcbs.com\/ja\/contact\/\"><strong>Get a Quote<\/strong><\/a> \u2014 Send your Gerber, BOM, CPL and assembly drawing. Our engineers reply with a consistency check, DFM notes and pricing within one working day.<\/p>\n<h2>Related reading<\/h2>\n<ul class=\"post-list\">\n<li><a href=\"https:\/\/ycpcbs.com\/ja\/pcb-component-sourcing\/\">component sourcing rules<\/a><\/li>\n<li><a href=\"https:\/\/ycpcbs.com\/ja\/pcb-assembly-process\/\">the assembly process<\/a><\/li>\n<li><a href=\"https:\/\/ycpcbs.com\/ja\/pcb-assembly\/\">turnkey PCB assembly<\/a><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>What a BOM and CPL file must contain for PCB assembly, the fields that cause rework, rotation traps, and how to check both files before sending.<\/p>","protected":false},"author":1,"featured_media":1841,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[98],"tags":[],"class_list":["post-4289","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-pcb-assembly"],"_links":{"self":[{"href":"https:\/\/ycpcbs.com\/ja\/wp-json\/wp\/v2\/posts\/4289","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ycpcbs.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ycpcbs.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ycpcbs.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ycpcbs.com\/ja\/wp-json\/wp\/v2\/comments?post=4289"}],"version-history":[{"count":1,"href":"https:\/\/ycpcbs.com\/ja\/wp-json\/wp\/v2\/posts\/4289\/revisions"}],"predecessor-version":[{"id":4318,"href":"https:\/\/ycpcbs.com\/ja\/wp-json\/wp\/v2\/posts\/4289\/revisions\/4318"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ycpcbs.com\/ja\/wp-json\/wp\/v2\/media\/1841"}],"wp:attachment":[{"href":"https:\/\/ycpcbs.com\/ja\/wp-json\/wp\/v2\/media?parent=4289"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ycpcbs.com\/ja\/wp-json\/wp\/v2\/categories?post=4289"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ycpcbs.com\/ja\/wp-json\/wp\/v2\/tags?post=4289"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}